2C/12AWG Stranded CL3R(CL2R) Fire Alarm Cable

2C/12AWG Stranded CL3R(CL2R) Fire Alarm Cable. Professional fire-resistant cable for fire alarm and emergency systems. LSZH sheath, PH30-PH120 fire rating, certified to BS EN 50200.

,

TL;DR

The 2C/12AWG Stranded CL3R(CL2R) Fire Alarm Cable is a BS EN 50200 and IEC 60331 certified fire-resistant cable rated for 300V/600V, supporting PH30-PH120 fire ratings, designed for fire alarm systems, emergency lighting, and safety circuits in commercial and industrial buildings.

Product Overview

According to international fire safety standards, fire alarm cables like the 2C/12AWG Stranded CL3R(CL2R) are critical components in building life safety systems. This professional fire-resistant cable is engineered for fire alarm systems, emergency lighting, voice alarm systems, and safety circuits—meeting BS 6387, BS EN 50200, and IEC 60331 certification requirements for fire safety applications. Available in stranded copper conductor configurations from 14–22 AWG, it provides reliable signal transmission in demanding environments.

Specifications

  • Conductor: Stranded copper, 12 AWG (also available in 14–22 AWG)
  • Insulation: Cross-linked polyolefin or ceramic silica gel
  • Sheath: Low Smoke Zero Halogen (LSZH) or PVC jacket options
  • Voltage Rating: 300V or 600V
  • Temperature Range: -40°C to +90°C
  • Fire Rating: PH30, PH60, PH90, PH120 — as per BS EN 50200

Key Features

  • Fire resistance rating: 30, 60, 90, and 120 minutes (PH30–PH120) per BS EN 50200
  • Low smoke emission under fire conditions — meets IEC 61034
  • Halogen-free construction — complies with IEC 60754 for reduced toxic gas release
  • Flame retardant — certified to IEC 60332
  • BS EN 50200 and IEC 60331 certified for circuit integrity during fire
  • Excellent signal transmission for fire alarm and voice evacuation systems
  • UL listed options available for North American installations

Applications

  • Fire alarm systems (conventional and addressable)
  • Emergency lighting circuits
  • Smoke detection systems
  • Voice alarm and public address systems
  • Fire fighting equipment power and control connections
  • Building automation and BMS integration
  • Commercial and industrial building life safety systems

Standards & Certifications

  • BS 6387 — fire survival performance
  • BS EN 50200 — circuit integrity for fire-resisting cables
  • IEC 60331 — fire withstand test for cables
  • IEC 60332 — flame retardant test
  • IEC 61034 — low smoke emission measurement
  • IEC 60754 — halogen content determination
  • UL listed options available

Why Choose This Cable?

Compared to standard wiring, the CL3R(CL2R) fire-rated cable maintains circuit integrity during a fire event—as tested to IEC 60331 and certified per BS EN 50200. Its Low Smoke Zero Halogen (LSZH) sheath reduces toxic gas emissions, protecting building occupants and emergency personnel. The wide temperature range of -40°C to +90°C ensures reliable performance in both indoor and outdoor fire safety installations, from commercial high-rises to industrial facilities.